How to add and reset Dome products on Hubitat Elevation hub
Authored by: Support.com Tech Pro Team
1. Introduction
How to add and reset Dome products on Hubitat Elevation hub
2. Resolution
Door / Window Sensor
Product Number
Device Type
Protocol
DMWD1
Contact Sensor
Z-Wave
Factory Reset
Open the Cover and make sure the Door/Window Sensor is powered.
Hold the Connect Button for 10 seconds until the LED indicator flashes once, then release the button.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Remove the Cover of the Door/Window Sensor.
Press the Connect Button quickly 3 times in a row. The LED indicator will flash 5 times indicating successful inclusion to the Z-Wave network.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Remove the Cover of the Door/Window Sensor.
Press the Connect Button quickly 3 times in a row. The LED indicator will flash 5 times indicating successful exclusion from the Z-Wave network.
Product Number
Device Type
Protocol
DMDP1
Contact Sensor
Z-Wave
Factory Reset
Remove the Sensor Cover and confirm that your Door/Window Sensor is powered up.
Wait for 5 seconds.
Move the Magnet and Sensor Base in and out of the closed position 6 times.
The LED indicator will light up Red for 5 seconds when reset successfully. The Door/Window Sensor’s memory will be erased to factory settings.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Remove the Sensor Cover and the LED indicator will start flashing yellow.
Press the Button quickly 3 times in a row.
The device will enter inclusion mode for two minutes and the LED indicator will alternate between green and red. After successful inclusion, the LED Indicator will flash green 3 times then flash red until the cover is replaced.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Remove the SENSOR COVER and the LED indicator will start flashing red.
Press the Button quickly 3 times in a row.
The LED Indicator will flash green 3 times indicating successful exclusion from the Z-Wave network. It will continue flashing red (indicating tamper) until the cover is replaced.
Leak Sensor
Product Number
Device Type
Protocol
DMWS1
Water Sensor
Z-Wave
Factory Reset
Open the Back Plate and make sure the Leak Sensor is powered.
Hold the Connect Button for 10 seconds until the LED indicator flashs once, then release the button.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Remove the cover of the Leak Sensor by twisting it apart.
Press the Connect Button quickly 3 times in a row. The LED indicator will flash 5 times indicating inclusion.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Remove the cover of the Leak Sensor by twisting it apart.
Press the Connect Button quickly 3 times in a row. The LED indicator will flash 5 times indicating successful exclusion from the Z-Wave network.
Product Number
Device Type
Protocol
DMMS1
Water Sensor
Z-Wave
Factory Reset
Remove the Cover and make sure the Motion Detector is powered.
Hold the Connect Button for 10 seconds until the LED indicator flashes once, then release the button.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Remove the cover of the Motion Detector by twisting it apart.
Press the Connect Button quickly 3 times in a row.
The LED indicator will flash 5 times indicating successful inclusion to the Z-Wave network.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Remove the cover of the Motion Detector by twisting it apart and make sure the Motion Detector is powered.
Press the Connect Button quickly 3 times in a row. The LED indicator will flash 5 times indicating successful exclusion from the Z-Wave network.
Mouser
Product Number
Device Type
Protocol
DMMZ1
Mouse Trap
Z-Wave
Factory Reset
Remove the TOP COVER by sliding it back and lifting up. Confirm that your Mouser is powered up.
Press and hold the CONNECT BUTTON for at least 10 seconds then release.
A flashing LED indicator indicates a successful factory reset. The Mousers memory will be erased to factory settings.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Remove the TOP COVER by sliding it back and lifting up. Confirm that your Mouser is powered up.
Press the CONNECT BUTTON quickly 3 times in a row.
The LED indicator will flash 5 times indicating successful inclusion to the Z-Wave network.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Remove the TOP COVER by sliding it back and lifting up. Confirm that your Mouser is powered up.
Press the CONNECT BUTTON quickly 3 times in a row. The LED indicator will flash 5 times indicating successful exclusion from the Z-Wave network.
On/Off Plug-In Switch
Product Number
Device Type
Protocol
DMOF1
Switch
Z-Wave
Factory Reset
Plug in the On/Off Plug-In Switch.
Hold the Connect Button for 10 seconds until the LED Indicator flashes once, then release the button.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Press the Connect Button quickly 3 times in a row. The LED indicator will flash 5 times indicating successful inclusion to the Z-Wave network.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Plug in the On/Off Plug-In Switch within range of your Z-Wave Controller.
Press the Connect Button quickly 3 times in a row. The LED indicator will flash 5 times indicating successful exclusion from the Z-Wave network.
Range Extender
Product Number
Device Type
Protocol
DMEX1
Repeater
Z-Wave
Factory Reset
Hold the Button for 10 seconds until the LED flashes 10 times, then release the button
Join the Z-Wave Network
For proper inclusion, install the Range Extender in the final location where it will be used.
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Plug the Range Extender into an outlet or use a micro USB (not included) to power it. The LED will flash 5 times indicating successful inclusion.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Press the Button quickly 3 times in a row The LED will flash 5 times indicating successful exclusion.
Siren
Product Number
Device Type
Protocol
DMS01
Siren
Z-Wave
Factory Reset
Open the Back Plate and make sure the Siren is powered.
Hold the Connect Button for 10 seconds until the LED Ring flashs once, then release the button.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Remove the Back Plate of the Siren.
Press the Connect Button quickly 3 times in a row. The LED Ring will flash 5 times indicating successful inclusion to the Z-Wave network.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Remove the Back Plate of the Siren.
Press the Connect Button quickly 3 times in a row. The LED Ring will flash 5 times indicating successful exclusion from the Z-Wave network.
Water Main Shut-Off
Product Number
Device Type
Protocol
DMWV1
Shutoff Valve
Z-Wave
Factory Reset
Press and hold the open/close button for at least 10 seconds then release.
The Shut-Off’s memory will be erased to factory settings. A flashing light indicates a successful factory reset.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Make sure the Water Main Shut-Off is powered on, then press the “open/close†button quickly 3 times in a row. The LED will stop flashing and stay on continuously upon successful inclusion.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
When prompted, press the “open/close†button on the Shut-Off quickly 3 times in a row.