Button
Product Number
Device Type
Protocol
FGBS-001
Contact Sensor
Z-Wave
Factory Reset
Remove and re-connect the power supply while holding down the B button
After 10 seconds, remove and re-connect the power supply again.
The settings of the device will be reset.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Quickly press the B button 3 times (the button is located in the center of the device).
Watch the status on the device details page to confirm proper operation.
Every time changes are made to the configuration of TP and TD lines (1-wire), (i.e. When DS18B20 temperature sensors are Included or Excluded), it is necessary to perform exclusion and repeated inclusion of the sensor modules to the hub. The system will enter into the programming mode only once all the connected sensors have been detected (about 10 seconds).
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Quickly press the B button 3 times (the button is located in the center of the device).
Wait for the removing process to end.
The device will be excluded from the Z-Wave network.
Product Number
Device Type
Protocol
FGPB-101
Outlet
Z-Wave
Factory Reset
Click the Button exactly five times.
Press and hold the button for at least 5 seconds.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Click the button at least 6 times.
Wait for the device to be added into the system, successful inclusion will be confirmed by Hubitat Elevationâ„¢
Click the button 4 times to wake it up
Watch the status on the device details page to confirm proper operation.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Click the Button at least 6 times.
Wait for the removing process to end.
The device will be excluded from the Z-Wave network.
Door/Window Sensor 2
Product Number
Device Type
Protocol
FGDW-002
Contact Sensor
Z-Wave
Factory Reset
Open the cover and remove the battery.
Install the battery while holding both TMP buttons.
The LED indicator will be flashing slowly for 5 seconds, but keep holding the buttons.
Release one button when the LED indicator starts flashing quickly.
Click the released button once to confirm the initiation of the reset procedure.
Wait a few seconds for a long flash of the LED indicator. Do not remove the battery.
The LED indicator will flash 5 times quickly to confirm the reset of the device.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Press one of the TMP buttons quickly, 3 times in a row, while keeping the other button pressed.
Wait for the inclusion process to end.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢
Watch the status on the device details page to confirm proper operation.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Press one of the TMP buttons quickly, 3 times in a row, while keeping the other button pressed.
The device will be excluded from the Z-Wave network.
Flood Sensor
Product Number
Device Type
Protocol
FGFS-101 FG3
Water Sensor
Z-Wave
Factory Reset
Make sure the sensor is powered.
Press and hold the TMP button.
Wait for the visual LED indicator to glow yellow (4th position of the MENU).
Release the TMP button.
Click the TMP button once to confirm the selection.
After a few seconds, the device will restart with factory settings, which are signaled with the red visual indicator color and an acoustic signal.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Removed the battery for 10 seconds, and re-install it
Wait for the inclusion process to end.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢
Watch the status on the device details page to confirm proper operation.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Press the TMP button quickly, 3 times in a row.
The device will be excluded from the Z-Wave network.
Product Number
Device Type
Protocol
FGFS-101 ZW5
Water Sensor
Z-Wave Plus
Factory Reset
Make sure the sensor is powered.
Press and hold the TMP button.
Wait for the visual LED indicator to glow yellow (4th position of the MENU).
Release the TMP button.
Click the TMP button once to confirm the selection.
After a few seconds, the device will restart with factory settings, which are signaled with the red visual indicator color and an acoustic signal.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Press the TMP button quickly, 3 times in a row.
Wait for the inclusion process to end.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢
Watch the status on the device details page to confirm proper operation.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Press the TMP button quickly, 3 times in a row.
The device will be excluded from the Z-Wave network.
KeyFob
Product Number
Device Type
Protocol
FGKF-601 ZW5
Button Controller
Z-Wave Plus
Factory Reset
Click O and – simultaneously.
Click ∆ or X until LED is Yellow - reset the device.
Click + to confirm selection or is you do not wish to reset at this time, click – to exit the menu.
The LED will pulse Yellow twice to confirm the device has been reset.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
LED will pulse White during the adding process.
Wait for the inclusion process to end.
Successful adding will be confirmed by the Z-Wave controller’s message.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢ and the remote LED will be Green.
Watch the status in the device details page to confirm proper operation.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Click O and – simultaneously.
Click ∆ or X until LED is Green.
Click + to confirm selection.
The device will be excluded from the Z-Wave network.
Motion Sensor
Product Number
Device Type
Protocol
FGMS-001 ZW5
Motion Sensor
Z-Wave Plus
Factory Reset
Open the cover
Press and hold the B-button.
Wait for visual indicator to glow Yellow (2nd menu position).
Release the B button and then briefly click the B-button to confirm selection
After few seconds the device will be reset, which is signaled with the Red, fading visual indicator color.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Press the B button quickly, three times in a row.
Wait for the inclusion process to end.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢
Watch the status in the device details page to confirm proper operation.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Press the B button quickly, three times in a row.
The device will be excluded from the Z-Wave network.
RGBW Controller
Product Number
Device Type
Protocol
FGRGBW-101
RGBW Controller
Z-Wave
Factory Reset
Disconnect the supply voltage.
Press and hold the B button located inside the RGBW Controllers casing.
Connect the the supply voltage, while still holding the B button.
Release the B button.
The B channel will turn on (blue channel).
Disconnect the power supply.
Join the Z-Wave Network
(Auto Inclusion)
Make sure the RGBW Controller is not connected to a supply.
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Connect voltage supply to auto-include the RGBW Controller.
The RGBW Controller will be automatically recognized and included in the Z-Wave network.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢
Watch the status in the device details page to confirm proper operation.
(Manual Inclusion)
Make sure the RGBW Controller is not connected to a supply.
To disable auto-inclusion press the B button briefly, after re-connecting the RGBW Controller to its supply voltage.
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Triple click the B button or any switch connected to I1-I4 inputs.
The RGBW Controller will be recognized and included in the Z-Wave network.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢
Watch the status in the device details page to confirm proper operation.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Triple click the B button or any switch connected to I1-I4 inputs.
The device will be excluded from the Z-Wave network.
Single Switch 2
Product Number
Device Type
Protocol
FGS-213
Switch
Z-Wave Plus
Factory Reset
Switch off the mains voltage (disable the breaker).
Remove the Switch 2 from the wall switch box.
Switch on the mains voltage.
Press and hold the B button to enter the menu until the visual LED indicator is Yellow.
Quickly release and click the B button again.
After few seconds the device will be restarted, which is signaled by the Red LED indicator color.
Join the Z-Wave Network
Identify the S1 switch.
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Quickly, three times press the S1 switch.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢
Watch the status in the device details page to confirm proper operation.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
Identify the S1 switch on the Fibaro Single Switch 2 From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Quickly, three times press the S1 switch.
The device will be excluded from the Z-Wave network.
Radiator Thermostat
Product Number
Device Type
Protocol
FIBEFGT-001
Thermostat
Z-Wave Plus
Factory Reset
Press and hold the button at the base of the thermostat head.
Release when the LED ring is Yellow.
Briefly press the button to confirm selection.
The device will reset and then go into Standby Mode.
Briefly press the button to activate the thermostat again.
Join the Z-Wave Network
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Quickly 3 times in a row, press the at the base of the thermostat head.
The LED ring will start flashing White.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢ and the LED ring will show Green.
Watch the status in the device details page to confirm proper operation.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
Quickly 3 times in a row, press the at the base of the thermostat head.
The LED ring will start flashing White.
Successful exclusion will be confirmed by Hubitat Elevationâ„¢ and the LED ring will show Red.
Wall Plug
Product Number
Device Type
Protocol
FGWPB-111 / FGWPB-121
Outlet
Z-Wave Plus
Factory Reset
Make sure the device is powered.
Press and hold the button.
Wait for the LED frame to glow yellow (3rd menu position).
Release the button and then briefly click the button once to confirm the selection.
After few seconds the device will restart with factory settings, which is signaled with the red frame color.
Join the Z-Wave Network
Plug the device into a socket.
The LED frame will glow red signaling it has not being added (If is doesn't you must first perform a general exclusion and then a factory reset).
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Quickly, triple click the button located on the casing.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢
Watch the status in the device details page to confirm proper operation.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
Plug the device into a socket.
Identify the S1 switch on the Fibaro Single Switch 2 From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
The LED frame will glow green signaling it is currently included in a Z-Wave network (If it doesn't, then the exclusion process is not needed at this time).
Quickly, triple click the button located on the casing.
The device will be excluded from the Z-Wave network.
Product Number
Device Type
Protocol
FGWPE-102
Outlet
Z-Wave
Factory Reset
Press and hold the button located on the side.
The device will cycle through GREEN, then VIOLET, and finally YELLOW for device reset.
Release the button.
Press the button again to confirm the selection and factory reset the device.
Join the Z-Wave Network
Plug the device into a socket nearby the main Z-Wave controller.
The LED frame will glow red signaling not being added (reset or remove the device otherwise).
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Quickly, triple click the button on the side of the device.
The device will be included to the Z-Wave network.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Quickly, triple click the button on the side of the device.
Plug the device into a socket nearby the main Z-Wave controller.
The LED frame will glow green signaling being added (removing is not necessary otherwise).
Quickly, triple click the button on the side of the device.
The device will be excluded from the Z-Wave network.
Dimmer 2
Product Number
Device Type
Protocol
FGS-212
Switch
Z-Wave Plus
Factory Reset
Switch off the mains voltage (disable the breaker).
Remove the Dimmer 2 from the wall switch box.
Switch on the mains voltage.
Press and hold the B button to enter the menu until the visual LED indicator is Yellow.
Quickly release and click the B button again.
After few seconds the device will be restarted, which is signaled by the Red LED indicator color.
The device enters the calibration mode.
Join the Z-Wave Network
Identify switch no. 1 (turns the light on) or the B-button (located on the device’s housing).
From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
Quickly press switch no. 1 or the B button three times.
Successful inclusion will be confirmed by Hubitat Elevationâ„¢
Watch the status in the device details page to confirm proper operation.
Exclusion from the Z-Wave Network
From the device's details page, select Remove Device, then Remove
Identify the S1 switch on the Fibaro Single Switch 2 From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
Quickly press switch no. 1 or the B button three times.
The device will be excluded from the Z-Wave network.