How to add and reset Remotec products on Hubitat Elevation hub

Authored by: Support.com Tech Pro Team

1. Introduction

 

How to add and reset Remotec products on Hubitat Elevation hub

 

2. Resolution

Factory Reset

  1. Factory reset is accomplished by excluding the device from the Z-Wave network
  2. From the device's details page, select Remove Device, then Remove
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  4. Click once on the PROG button or and external attached switch.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Click once on the PROG button or and external attached switch.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Click once on the PROG button or and external attached switch.

Device

Product Number

Device Type

Protocol

Relay / Fixture Switch

ZFM-80US/DA065

Relay

Z-Wave

Device

Product Number

Device Type

Protocol

ZRC-90 Scene Master

REMEZRC90

Button Controller

Z-Wave Plus

Factory Reset

  1. Press and keep holding the R button not less than 10 seconds.
  2. Release the R button then triple-click on the same R button within 2 seconds.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press L & R buttons simultaneously until the LED lights up to add the device to the Z-Wave network. The LED will keep flashing slowly.
  3. Press the program button. The LED will flash once, then remain off if the device is included in the Z-Wave network.
  4. If the LED flashes 6 times rapidly, then remains off, the device has failed to be included in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Click once on the R button to remove the device from the Z-Wave network. The LED will continue flashing slowly.
  4. Press the program button. The LED will flash once, then remain off if the device is excluded from the Z-Wave network.
  5. If the LED flashes 6 times rapidly, then remains off, the device has failed to be excluded in the Z-Wave network.
  6. Perform a factory reset and repeat the above steps to exclude the device from the Z-Wave network.